• Mon-Fri 7:30-17:30 I Sat -Sun Closed

Ghaddar Gas Generator KG16LP – KG15NG (50 Hz) powered by Kubota

Product description

General  Set Rating

Voltage*¹

230/400 V

Frequency

50 Hz

LPG Gas

Standby Rating*2

17.5 kVA

Continuous Rating*3

16 kVA

Natural Gas

Standby Rating*2

16.3 kVA

Continuous Rating*3

15 kVA

Ghaddar Gas Generator KG16LP – KG15NG (50 Hz) powered by Kubota

The above ratings represent the generating set capability guaranteed within ±3% at the reference conditions equivalent to those specified in ISO 8528/1 standard.

Notes

  1. The applicable voltage range is 380V to 415V for 50Hz applications. For other voltages, please consult factory.
  2. Standby rating: variable load limited to an annual usage up to 500 hours, of which 300 hours may be continuous running. No overload is permitted.
  3. Continuous rating: is the maximum power available for continuous loads for unlimited running hours a year between the maintenance times recommended by the manufacturer under the environmental conditions.

Engine Technical Data

Make & Model KUBOTA WG1605
Cylinders & Arrangement In-line, 4 Cylinder
Bore & Stroke (mm) 79.0 × 78.4
Induction system Naturally aspirated
Ignition Full transistor battery ignition type
Cycle 4 stroke
Compression ratio 9.1:1
Cooling System Water cooled
Displacement (Liters) 1.537
Lube oil capacity (Liters) 6.0
Coolant capacity (Liters) 4.0
Engine Speed (rpm) 1500
Governor Electronic
Minimum gas inlet pressure (mbar) 1 MPa
Max allowed inlet pressure (mbar) 5 KPa
Fuel Types LPG Gas Natural Gas
Fuel Consumption (g/kWh) 241 222
Radiator cooling air flow (m³/min) 26.1 29
Max exhaust gas flow (m3/min) 2.56 2.04
Exhaust temperature ºC (max) 650 600
Exhaust Back Pressure (KPa) 4.3
The above performance data are valid as per the following specs:
  • Natural Gas is methane based. LPG is propane based.
  • Lubricating oil specification should exceed API CE, SAE 15W-40.
  • The coolant should be 50% inhibited glycol and 50% fresh water..

Alternator Technical Data

Make & Model Leroy Somer TAL040F
Frequency / No. of poles 50Hz / 4P
Ingress protection IP23
Insulation class H
Terminals (Optional) 6 (12)
Excitation system SHUNT
Winding pitch 2/3
AVR model R120
Overspeed 2250 R.P.M.
Voltage regulation ±1%
Coolant air flow 0.06 m3/s

Certification

  • The complete generating set is type-tested according to ISO 8528-8 standard.

Control Panel Specifications

GMP260MKIII (DSE6110 MKIII) panel is an automatic start genset panel of microprocessor-based design, capable of CAN-bus J1939 interface with electronic engines. Configurable via PC software or fascia buttons. Optional DSE6120MKIII for mains monitoring. Circuit breaker: Schneider or ABB, 3P MCB (4P optional).

Construction

Sheet Fabrication CNC shearing & bending
Paint type Heat-treated powder-coated
Paint application Electrostatic corona spraying
Durability tests
  • Impact [EN ISO 6272]
  • Salt spray resistance [ASTM B117-73]
  • Humidity resistance [ASTM D2247]
Compliance
  • Compliant with [ISO8528-8]
  • Clearance & Creepage [IEC60355-1]
  • Leakage current & Dielectric strength [IEC60355-1]
  • Protection against electric shock [IEC600 364-4-41]
Degree of protection IP55
Wire crimping
  • Crimping force up to 20 kN
  • Accuracy of 0.01 mm
  • Each crimp checked by Komax CFA+
Wire coding
  • Coded by color and cross-section
  • Coded by printed numbers
  • Coded by printed function of the wire

Certification

  • The control panel is certified by an ISO17025 accredited laboratory to have IP55 according to IEC60355.

Genset Standard Features

Assembly: Gensets are assembled at Ghaddar Machinery Factory in compliance with ISO 8528. Fabrication:
  • Engine/alternator assembly rests on skid with anti-vibration mounting pads.
  • Skid made of durable sheet metals and beams exceeding “Vibration & Torsion” resistance norms.
  • Skid-mounted fuel tank supplied with fuel gauge, filler cap, fuel inlet and outlet hoses.
  • Control panel enclosure made of reliable metal sheet.
Paint:
  • Skid and control panel enclosure painted with heat-treated, powder-coated electrostatic corona spraying.
  • Paint durability tested against:
    • Impact (EN ISO 6272)
    • Salt Spray Resistance (ASTM B117-73)
    • Humidity Resistance (ASTM D2247)
Works-Testing:
  • All gensets tested prior to dispatch.
  • Test automatically generated and checked according to ISO8528.
  • Test certificate issued for each genset.
Equipment:
  • Water-cooled radiator with belt-driven blower fan and full guarding
  • Electric starter with solenoid relay
  • Battery charging alternator
  • Energized-to-run solenoid
  • Replaceable fuel, oil and air filters
  • Heavy-duty lead-acid battery with matching capacity (Amps & CCA)
  • Gas train.
Documentation:
  • User Manual (Operation, Installation, Maintenance)
  • Wiring Diagram
  • Test Report
  • Maintenance Schedule
  • Catalogues for Engine, Alternator & AVR

Genset Optional Features

  • Manual & Automatic Transfer Switches
  • Synchronizing & Totalizing Panels
  • Fuel water separator
  • Water jacket heater
  • Oil heater
  • Fuel heater
  • Battery heater
  • Anti-condensation heater
  • Air Shut-off Valve
  • Oil Sampler
  • Pre-lube Oil Pump
  • Gas detectors
  • Industrial exhaust silencer – 16 DB noise reduction level

Shipping Dimensions (Open Set):

  • Length: 1400 mm
  • Width: 610 mm
  • Height: 1110 mm
  • Weight: 340 Kg