• Mon-Fri 7:30-17:30 I Sat -Sun Closed

Ghaddar Generator CT370 – CT410S (50 Hz) powered by Cummins

Product description

Ratings @ 0.8 PF

Voltage*

230/400 V

Frequency*

50 Hz

Prime rating

CT370*

370 KVA

Stand-by Rating

CT410S*

410 KVA

Ghaddar Generator CT370 – CT410S (50 Hz) powered by Cummins

The above ratings represent the generating set capability guaranteed within ±3% at the reference conditions equivalent to those specified in ISO 8528/1 standard.

Notes

  1. The applicable voltage range is 380V to 415V for 50Hz applications. For other voltages, please consult factory.
  2. This generating set is of fixed speed of 1500 rpm.
  3. CT370 (prime power): variable load and unlimited hour usage with an average load factor of 80% of the prime rating over each 24-hour period. A 10% overload is permitted for 1 hour in every 12 hours of operation.
  4. CT410 (standby power): variable load limited to an annual usage up to 500 hours, of which 300 hours may be continuous running. No overload is permitted.

Engine Technical Data

Make & ModelCUMMINS QSG12-G3
Cylinders & Arrangement6; Vertical in-line
Bore & Stroke (mm)132 × 144
Induction systemTurbocharged & Aftercooled
CombustionDirect injection
Cycle4 stroke
Compression ratio17.0:1
Cooling SystemWater cooled
Displacement11.8 liters
Lube oil capacity34 liters Max
Coolant capacity48 liters
Standard governorElectronic; Cummins CM2880
Engine Speed (rpm)1500
Consumption @ 100% Load (L/H) 72
Consumption @ 75% Load (L/H) 54
Consumption @ 50% Load (L/H)37
Consumption @ 25% Load (L/H)20
Radiator Cooling Air Flow (m3/s)8.4
Emissions regulationsFuel optimized
Exhaust temperature (°C, max)457
Max exhaust gas flow (m3/min)49.4
Max. allowed back pressure (kPa)10.2

The above performance data are valid as per the following specs:

  • Diesel fuel according to BS2869 Class A2 or equivalent.
  • Lubricating oil according to Grade SAE 15W-40 API CI4.
  • Coolant mixture: 50% antifreeze and 50% fresh water.

Alternator Technical Data

Make & ModelLeroy Somer TAL046H
Frequency / No. of poles50Hz / 4P
Ingress protectionIP23
Insulation classH
Terminals (Optional)6 (12)
Excitation system (Optional)SHUNT (AREP +or PMG)
Winding pitch2/3
AVR modelR150
Overspeed2250 R.P.M.
Voltage regulation±1%
Coolant air flow0.48 m3/s

Certification

  • The complete generating set is type-tested according to ISO 8528-8 standard.

Control Panel Specifications

GMP260MKIII (DSE6110 MKIII) panel is an automatic start genset panel of microprocessor-based design, capable of CAN-bus J1939 interface with electronic engines. Configurable via PC software or fascia buttons.
Optional DSE6120MKIII for mains monitoring. Circuit breaker: Schneider or ABB, 3P MCB (4P optional).

 

Construction

Sheet FabricationCNC shearing & bending
Paint typeHeat-treated powder-coated
Paint applicationElectrostatic corona spraying
Durability tests
  • Impact [EN ISO 6272]
  • Salt spray resistance [ASTM B117-73]
  • Humidity resistance [ASTM D2247]
Compliance
  • Compliant with [ISO8528-8]
  • Clearance & Creepage [IEC60355-1]
  • Leakage current & Dielectric strength [IEC60355-1]
  • Protection against electric shock [IEC600 364-4-41]
Degree of protectionIP55
Wire crimping
  • Crimping force up to 20 kN
  • Accuracy of 0.01 mm
  • Each crimp checked by Komax CFA+
Wire coding
  • Coded by color and cross-section
  • Coded by printed numbers
  • Coded by printed function of the wire

Certification

  • The control panel is certified by an ISO17025 accredited laboratory to have IP55 according to IEC60355.

Genset Standard Features

Assembly: Gensets are assembled at Ghaddar Machinery Factory in compliance with ISO 8528.

Fabrication:

  • Engine/alternator assembly rests on skid with anti-vibration mounting pads.
  • Skid made of durable sheet metals and beams exceeding “Vibration & Torsion” resistance norms.
  • Skid-mounted fuel tank supplied with fuel gauge, filler cap, fuel inlet and outlet hoses.
  • Control panel enclosure made of reliable metal sheet.

Paint:

  • Skid and control panel enclosure painted with heat-treated, powder-coated electrostatic corona spraying.
  • Paint durability tested against:
    • Impact (EN ISO 6272)
    • Salt Spray Resistance (ASTM B117-73)
    • Humidity Resistance (ASTM D2247)

Works-Testing:

  • All gensets tested prior to dispatch.
  • Test automatically generated and checked according to ISO8528.
  • Test certificate issued for each genset.

Equipment:

  • Water-cooled radiator with belt-driven blower fan and full guarding
  • Electric starter with solenoid relay
  • Battery charging alternator
  • Energized-to-run solenoid
  • Replaceable fuel, oil and air filters
  • Heavy-duty lead-acid battery with matching capacity (Amps & CCA)
  • Industrial exhaust silencer – 16 dB noise reduction.
  • Integral Fuel Tank with 400 L capacity

Documentation:

  • User Manual (Operation, Installation, Maintenance)
  • Wiring Diagram
  • Test Report
  • Maintenance Schedule
  • Catalogues for Engine, Alternator & AVR

Genset Optional Features

  • Manual & Automatic Transfer Switches
  • Synchronizing & Totalizing Panels
  • Fuel water separator
  • Water jacket heater
  • Oil heater
  • Fuel heater
  • Battery heater
  • Anti-condensation heater
  • Air Shut-off Valve
  • Oil Sampler
  • Pre-lube Oil Pump

Shipping Dimensions (Open Set):

  • Length: 3200 mm
  • Width: 1100 mm
  • Height: 2000 mm
  • Weight: 2700 Kg