Ratings @ 0.8 PF

Voltage*

230/400 V

Frequency*

50 Hz

Prime rating

PT24*

20 KVA

Stand-by Rating

PT27S*

22 kVA

Ghaddar Generator KT20 – KT22S 2003-T (1500 rpm) powered by Kubota

 

 

The above ratings represent the generating set capability guaranteed within ±3% at the reference conditions equivalent to those specified in ISO 8528/1 standard.

Notes

  1. The applicable voltage range is 380V to 415V for 50Hz applications. For other voltages, please consult factory.
  2. This generating set is of fixed speed of 1500 rpm.
  3. KT20 (prime power): variable load and unlimited hour usage with an average load factor of 80% of the prime rating over each 24-hour period. A 10% overload is permitted for 1 hour in every 12 hours of operation.
  4. KT22S (standby power): variable load limited to an annual usage up to 500 hours, of which 300 hours may be continuous running. No overload is permitted.

Engine Technical Data

Make & ModelKUBOTA V2003-T-E2-BG
Cylinders & Arrangement4; vertical in-line
Bore & Stroke (mm)83 x 92.4
Induction systemTurbocharged
CombustionIndirect injection
Cycle4 stroke
Compression ratio21.7
Cooling SystemWater cooled
Displacement1.999 liters
Lube oil capacity7.6 liters Max
Coolant capacity8.4 liters
Standard governorIsochronous Electronic
Engine Speed1500 rpm
Fuel Consumption @ 100% Load5.6 (L/H)
Fuel Consumption @ 75% Load4.2 (L/H)
Fuel Consumption @ 50% Load2.8 (L/H)
Fuel Consumption @ 25% Load1.4 (L/H)
Radiator Cooling Air Flow (m3/s)0.78
Emissions regulationsEU Stage IIIA
Exhaust temperature (°C, max)510
Max exhaust gas flow (m3/min)5.5
Max. allowed back pressure (kPa)7.1

The above performance data are valid as per the following specs:

  • Diesel Fuel according to BS2869 Class A2 or equivalent.
  • Lubricating oil according to Grade SAE 15W-40 API CI4.
  • Coolant mixture: 50% antifreeze and 50% fresh water.

Alternator Technical Data

Make & ModelLeroy Somer TAL040F
Frequency / No. of poles50Hz / 4P
Ingress protectionIP23
Insulation classH
Terminals (Optional)6 (12)
Excitation systemSHUNT
Winding pitch2/3
AVR modelR120
Overspeed2250 R.P.M.
Voltage regulation±1%
Coolant air flow0.06 m3/s

Certification

  • The complete generating set is type-tested according to ISO 8528-8 standard.

Control Panel Specifications

Control Panel GMP260MK

GMP260MK (DSE6010 MKII) panel is an automatic start generating-set panel of microprocessor-based design which is capable of interfacing with electronic engines through CAN-bus J1939. It is fully configurable by front fascia buttons and PC software. If mains voltage is to be monitored, DSE6020MKII can be offered. Circuit Breaker Schneider or ABB, 3-Pole MCB (4-Pole optional).

Construction

Sheet FabricationCNC shearing & bending
Paint typeHeat-treated powder-coated
Paint applicationElectrostatic corona spraying
Durability tests
  • Impact [EN ISO 6272]
  • Salt spray resistance [ASTM B117-73]
  • Humidity resistance [ASTM D2247]
Compliance
  • Panel compliant with [ISO8528-8]
  • Clearance & Creepage [IEC60355-1]
  • Leakage current & Dielectric strength [IEC60355-1]
  • Protection against electric shock [IEC600 364-4-41]
Degree of protectionIP55
Wire crimping
  • Crimping force up to 20 kN
  • Accuracy of 0.01 mm
  • Each crimp checked by Komax CFA+
Wire coding
  • Wires coded by color and cross-section
  • Wires coded by printed numbers
  • Wires coded by printed function of the wire

Genset Construction

Certification

  • The control panel is certified by an ISO17025 accredited laboratory to have IP55 according to IEC60355.

Genset Standard Features

Assembly: Gensets are assembled at Ghaddar Machinery Factory in compliance with ISO 8528 standard.

Fabrication:

  • Engine/alternator assembly rests on skid with anti-vibration mounting pads.
  • Skid made of durable sheet metals and beams exceeding vibration & torsion resistance norms.
  • Skid-mounted fuel tank supplied with fuel gauge, filler cap, fuel inlet and outlet hoses.
  • Control panel enclosure made of reliable metal sheet.

Paint:

  • Skid and control panel enclosure painted with heat-treated, powder-coated electrostatic corona spraying.
  • Paints passed durability tests conforming to international standards:
    • Impact (EN ISO 6272)
    • Salt Spray Resistance (ASTM B117-73)
    • Humidity Resistance (ASTM D2247)

Works-Testing:

  • All gensets are tested prior to dispatch.
  • Tests automatically generated and checked according to ISO8528.
  • Test certificate issued for each genset.

Equipment:

  • Water-cooled radiator with belt-driven blower fan and full guarding
  • Electric starter with solenoid relay
  • Battery charging alternator
  • Energized-to-run solenoid
  • Replaceable fuel, oil and air filters
  • Heavy-duty lead-acid battery with matching capacity (Amps & CCA)
  • Loose-supplied industrial exhaust silencer – 16 dB noise reduction
  • Integral fuel tank with 67 L capacity

Documentation:

  • User Manual (operation, installation, maintenance)
  • Wiring diagram
  • Test report
  • Maintenance schedule
  • Catalogues for Engine, Alternator & AVR

Genset Optional Features

  • Manual & Automatic Transfer Switches
  • Synchronizing & Totalizing Panels
  • Fuel water separator
  • Water jacket heater
  • Oil heater
  • Fuel heater
  • Battery heater
  • Anti-condensation heater
  • Air shut-off valve
  • Oil sampler
  • Pre-lube oil pump