Product description
Ratings @ 0.8 PF
Voltage*
220/380 V
127/220 V
277/480 V
Frequency*
60 Hz
60 Hz
60 Hz
Prime rating
KT50*
50 KVA
50 KVA
50 KVA
Stand-by Rating
KT56S*
56 KVA
56 KVA
56 KVA
Ghaddar Generator KT50– KT56S (1800 rpm) powered by Kubota
The above ratings represent the generating set capability guaranteed within ±3% at the reference conditions equivalent to those specified in ISO 8528/1 standard.
The above performance data are valid as per the following specs:
Note 1: Some OPTIONAL features could be standard if CANbus is established within electronic engines.
Note 2: Low coolant level protection is standard for gensets above 200 kVA; otherwise, it is optional.
Note 3: There is a limitation in the number of protections and measurements that can be offered with GMP260MK. Other control panels & modules can be offered as required (DSE 7310/20, 7410/20, 8610, 8810, and others).
Fabrication:
Notes
- The applicable voltage range is 220V, 380V to 480V for 60Hz applications. For other voltages, please consult factory.
- This generating set is of fixed speed of 1800 rpm.
- KT50 (prime power): variable load and unlimited hour usage with an average load factor of 80% of the prime rating over each 24-hour period. A 10% overload is permitted for 1 hour in every 12-hour operation.
- KT56S (standby power): variable load limited to an annual usage up to 500 hours, of which 300 hours may be continuous running. No overload is permitted.
Engine Technical Data
| Make & Model | KUBOTA 3800-T-DI-E2BG – GDR1 |
|---|---|
| Cylinders & Arrangement | 4; vertical in-line |
| Bore & Stroke (mm) | 100 × 120 |
| Induction system | Turbo Charged |
| Combustion | Direct injection |
| Cycle | 4 stroke |
| Compression ratio | 21:8 |
| Cooling System | Water cooled |
| Displacement | 3.769 liters |
| Lube oil capacity | 13.2 liters Max |
| Coolant capacity | 9 liters |
| Standard governor | Electronic |
| Engine Speed | 1800 rpm |
| Fuel Consumption @ 100% Load | 11.8 (L/H) |
| Fuel Consumption @ 75% Load | 9.0 (L/H) |
| Fuel Consumption @ 50% Load | 6.7 (L/H) |
| Fuel Consumption @ 25% Load | 4.9 (L/H) |
| Radiator Cooling Air Flow (m3/s) | 1.49 |
| Emissions regulations | EPA / CARB Tier 2 |
| Exhaust temperature (°C, max) | 500 |
| Max exhaust gas flow (m3/min) | 10.7 |
| Max. allowed back pressure (kPa) | 7.1 |
- Diesel fuel according to BS2869 Class A2 or equivalent.
- Lubricating oil according to Grade SAE 15W-40 API CI4.
- Coolant mixture: 50% antifreeze and 50% fresh water.
Alternator Technical Data
| Make & Model | Leroy Somer TAL042H / TAL042F8S |
|---|---|
| Frequency / No. of poles | 60Hz / 4P |
| Ingress protection | IP23 |
| Insulation class | H |
| Terminals (Optional) | 6 (12) |
| Excitation system | SHUNT |
| Winding pitch | 2/3 |
| AVR model | R120 |
| Overspeed | 2250 R.P.M. |
| Voltage regulation | ±1% |
| Alternator air flow | 3.1 m3/s |
Certification
- Complete generating set type-tested to ISO 8528-8.
- The control panel is certified by an ISO 17025 accredited laboratory to have IP55 according to IEC 60355.
Control Panel Specifications

Construction
| Sheet Fabrication | CNC shearing & bending |
|---|---|
| Paint type | Heat-treated powder-coated |
| Paint application | Electrostatic corona spraying |
| Durability tests |
|
| Compliance |
|
| Degree of protection | IP55 |
| Wire crimping |
|
| Wire coding |
|
Control Panel Protections, Control & Instrumentation
| Protection (standard) | (OPTIONAL Note 1,3) | Control (standard) | (OPTIONAL Note 1) | Instrumentation (standard) | (OPTIONAL Note 1,3) |
|---|---|---|---|---|---|
| Over / Under AC Voltage | High Oil Temperature | Remote Start Input | Battery Charger: 5A, 10A, UL | Gen AC Voltage: 3ph VLL & VLN | Lube Oil Temperature |
| Over / Under Frequency | High Exhaust Temperature | Emergency Stop Button | Fuel Pump Control | Gen Frequency: Hz | Exhaust Temperature |
| Delayed Over Current | Low Fuel Pressure | Common Alarm Volt-Free Contact | Extension: | Gen Current: 3 phase A | Engine inlet air (Boost) pressure |
| Short-circuit | Low Coolant Pressure | Event Log (100 Events) | Ethernet – Modbus TCP | Power: kW, kVA, kVAr & PF | Charging Ammeter |
| Over kW | Low Fuel Level | Weekly Exerciser | RS485 – Modbus RTU | Energy: kW·h, kVA·h, kVAr·h | Fuel Pressure |
| High Engine Temperature | Low Oil Level | Audible Alarm | GPS Tracker | Lube Oil Pressure | Coolant Pressure |
| Low Oil Pressure | High Winding Temperature | Standard CANbus J1939 | Water in Fuel Detection | Engine Coolant Temperature | Fuel Level |
| Maintenance Alarm | High Bearing Temperature | Pre/Post Heat Control | Webnet Applications | Battery DC Voltage | Lube Oil Level |
| High / Low Battery Voltage | Low Boost Pressure | Data Logging | SNMP Gateway | DC Alternator | Winding temperature 3×RTD |
| Low Coolant Level (Note 2) | Fusible Link Fire Protection | PLC Editor | Inputs: 20 mA, 10 V | Engine Speed | Bearing Temperature RTD |
| 3 ph Mains Sensing (6120) | Low Coolant Temperature | Oil Level Control | Thermocouples | Operating Hours | Tier 4 Support |
Note 2: Low coolant level protection is standard for gensets above 200 kVA; otherwise, it is optional.
Note 3: There is a limitation in the number of protections and measurements that can be offered with GMP260MK. Other control panels & modules can be offered as required (DSE 7310/20, 7410/20, 8610, 8810, and others).
Genset Standard Features
Assembly: Gensets are assembled at Ghaddar Machinery Factory in compliance with ISO 8528.Fabrication:
- Engine/alternator assembly rests on skid with anti-vibration mounting pads
- Skid made of durable sheet metals and beams exceeding vibration & torsion norms
- Skid-mounted fuel tank with fuel gauge, filler cap, fuel inlet and outlet hoses
- Control panel enclosure made of reliable metal sheet
- Heat-treated, powder-coated electrostatic corona spraying
- Durability tests conforming to international standards:
- Impact (EN ISO 6272)
- Salt Spray Resistance (ASTM B117-73)
- Humidity Resistance (ASTM D2247)
- All gensets tested prior to dispatch
- Automatic test generated and checked according to ISO 8528
- Test certificate issued for each genset
- Water-cooled radiator with belt-driven blower fan and full guarding
- Electric starter with solenoid relay
- Battery charging alternator
- Energized-to-run solenoid
- Replaceable fuel, oil and air filters
- Heavy-duty lead-acid battery with matching capacity (Amps & CCA)
- Industrial exhaust silencer – 16 dB noise reduction
- Integral fuel tank with 67 L capacity
- User Manual for operation, installation and maintenance
- Wiring diagram
- Test report
- Maintenance schedule
- Catalogues for Engine, Alternator & AVR
Genset Optional Features
- Manual & Automatic Transfer Switches
- Synchronizing & Totalizing Panels
- Fuel water separator
- Water jacket heater
- Oil heater
- Fuel heater
- Battery heater
- Anti-condensation heater
- Air shut-off valve
- Oil sampler
- Pre-lube oil pump
- Length: 1800 mm
- Width: 610 mm
- Height: 1160 mm
- Weight: 590 Kg