Ghaddar Generator KT9 – KT10S (1500 rpm) – 1 Phase powered by Kubota

Product description

Ratings @ 0.8 PF

Voltage*

230 V

Frequency*

50 Hz

Prime rating

KT 9*

8.8 KVA

Stand-by Rating

KT10*    Max Current
9.9A           32A         

Ratings @ 0.8 PF

Voltage*

230 V

Frequency*

50 Hz

Prime rating

KT 9*

8.8 KVA

Stand-by Rating

KT10*    Max Current
9.9A           32A         

Ratings @ 0.8 PF

Voltage*

230 V

Frequency*

50 Hz

Prime rating

KT9*

8.8KVA

Stand-by Rating

KT10*

9.9 A

Stand-by Rating

Max Current

32 A

Ghaddar Generator KT9 – KT10S (1500 rpm) – 1 Phase powered by Kubota

Ratings guaranteed within ±3% at ISO 8528/1 reference conditions.

Notes

  1. Applicable voltage: 230 V (single-phase, 50 Hz). For other voltages, please consult factory.
  2. Fixed speed: 1500 rpm.
  3. KT9 (Prime power): Variable load, unlimited hours; 80% average load factor over 24 h. 10% overload allowed 1 h / 12 h.
  4. KT10S (Standby power): Variable load; up to 500 h/year (300 h continuous). No overload permitted.

Engine Technical Data

Make & ModelKUBOTA D1105-E2-BG
Cylinders & Arrangement3; vertical in-line
Bore & Stroke (mm)78 × 78.4
Induction systemNaturally Aspirated
CombustionIndirect injection
Cycle4 stroke
Compression ratio24
Cooling SystemWater cooled
Displacement1.123 L
Lube oil capacity5.1 L (max)
Coolant capacity5.1 L
Standard governorMechanical +/-5% Electronic
Engine Speed1500 rpm
Fuel Consumption (L/h)100%: 2.45  | 
75%: 1.84  | 
50%: 1.23  | 
25%: 0.62
Radiator Cooling Air Flow0.35 m3/s
Emissions regulationsFor non-regulated territories
Exhaust temperature (max)500 °C
Max exhaust gas flow2.24 m3/min
Max. allowed back pressure7.1 

Performance data validity:

  • Diesel fuel per BS2869 Class A2 or equivalent.
  • Lubricating oil per SAE 15W-40 API CI4.
  • Coolant: 50% antifreeze / 50% fresh water.

Alternator Technical Data

Make & ModelLeroy Somer TAL040C
Frequency / Poles50 Hz / 4P
Ingress protectionIP23
Insulation classH
Terminals (Optional)6 (12)
Excitation systemSHUNT
Winding pitch2/3
AVR modelR120
Overspeed2250 rpm
Voltage regulation± 1%
Cooling air flow0.06 m3/s

Certification

  • Complete generating set type-tested to ISO 8528-8.
  • The control panel is certified by an ISO 17025 accredited laboratory to have IP55 according to
    IEC 60355

Control Panel Specifications

GMP260MK (DSE6110 MKIII) Control Panel

GMP260MK (DSE6110 MKIII): Automatic start panel; microprocessor-based with CAN-bus J1939 engine interface.
Fully configurable via front fascia buttons and PC software. For mains monitoring, DSE6120 MKIII is available.

Circuit Breaker: Schneider or ABB, 3-Pole MCB (4-Pole optional)

Construction

Sheet FabricationCNC shearing & bending
Paint typeHeat-treated powder-coated
Paint applicationElectrostatic corona spraying
Durability testsIMPACT [EN ISO 6272] • Salt spray [ASTM B117-73] • Humidity [ASTM D2247]
CompliancePanel compliant with ISO8528-8 • Clearance & Creepage IEC60355-1 • Leakage & Dielectric IEC60355-1 • Shock protection IEC600 364-4-41
Degree of protectionIP55
Wire crimpingForce up to 20 kN • 0.01 mm accuracy • Each crimp checked by Komax CFA+
Wire codingBy color & cross-section • Printed numbers • Printed function

Control Panel Protections, Control & Instrumentation

Protection (standard)

(OPTIONAL 

Note 1,3)

Control (standard)

(OPTIONAL 

Note 1)

Instrumentation (standard)(OPTIONAL Note 1,3)
Over / Under AC VoltageHigh Oil TemperatureRemote Start InputBattery Charger: 5A, 10A, ULGen AC Voltage: 3ph VLL & VLNLube Oil Temperature
Over / Under FrequencyHigh Exhaust TemperatureEmergency Stop ButtonFuel Pump ControlGen Frequency: HzExhaust Temperature
Delayed Over CurrentLow Fuel PressureCommon Alarm Volt-Free ContactExtension:Gen Current: 3 phase AEngine inlet air (Boost) pressure
Short-circuitLow Coolant PressureEvent Log (100 Events)Ethernet – Modbus TCPPower: kW, kVA, kVAr & PFCharging Ammeter
Over kWLow Fuel LevelWeekly ExerciserRS485 – Modbus RTUEnergy: kW·h, kVA·h, kVAr·hFuel Pressure
High Engine TemperatureLow Oil LevelAudible AlarmGPS TrackerLube Oil PressureCoolant Pressure
Low Oil PressureHigh Winding TemperatureStandard CANbus J1939Water in Fuel DetectionEngine Coolant TemperatureFuel Level
Maintenance AlarmHigh Bearing TemperaturePre/Post Heat ControlWebnet ApplicationsBattery DC VoltageLube Oil Level
High / Low Battery VoltageLow Boost PressureData LoggingSNMP GatewayDC AlternatorWinding temperature 3×RTD
Low Coolant Level (Note 2)Fusible Link Fire ProtectionPLC EditorInputs: 20 mA, 10 VEngine SpeedBearing Temperature RTD
3 ph Mains Sensing (6120)Low Coolant TemperatureOil Level ControlThermocouplesOperating HoursTier 4 Support

Note 1: Some OPTIONAL features could be standard if CANbus is established within electronic engines.

Note 2: Low coolant level protection is standard for gensets above 200 kVA; otherwise, it is optional.

Note 3: There is a limitation in the number of protections and measurements that can be offered with GMP260MK. Other control panels & modules can be offered as required (DSE 7310/20, 7410/20, 8610, 8810, and others).

Control Panel Certification

  • Certified by an ISO17025 accredited laboratory to IP55 per IEC60355.

Genset Standard Features

Assembly: Assembled at Ghaddar Machinery Factory in compliance with ISO 8528.

Fabrication:

  • Engine/alternator on skid with anti-vibration mounts
  • Durable sheet-metal skid & beams (exceed vibration & torsion norms)
  • Skid-mounted fuel tank with gauge, filler cap, inlet/outlet hoses
  • Metal sheet control-panel enclosure

Paint: Heat-treated, powder-coated; passed Impact (EN ISO 6272), Salt Spray (ASTM B117-73), Humidity (ASTM D2247).

Works-Testing: 100% tested prior to dispatch; automatic test per ISO8528; test certificate per genset.

Equipment:

  • Water-cooled radiator with belt-driven blower & guarding
  • Electric starter with solenoid relay; battery charging alternator
  • Energized-to-run solenoid; replaceable fuel/oil/air filters
  • Heavy-duty lead-acid battery (matched Amps & CCA)
  • Industrial exhaust silencer (16 dB reduction)
  • Integral fuel tank: 67 L

Documentation: User Manual • Wiring Diagram • Test Report • Maintenance Schedule • Engine/Alternator/AVR Catalogues

Genset Optional Features

  • Manual & Automatic Transfer Switches
  • Synchronizing & Totalizing Panels
  • Fuel water separator • Water jacket / Oil / Fuel / Battery heaters
  • Anti-condensation heater • Air Shut-off Valve • Oil Sampler • Pre-lube Oil Pump.

Shipping Dimensions (Open Set):

  • Length: 1400 mm
  • Width: 610 mm
  • Height: 1020 mm
  • Weight: 285 Kg