• Mon-Fri 7:30-17:30 I Sat -Sun Closed

Ghaddar Generator CT2250 – CT2500S (50 Hz) powered by Cummins

Product description

Ratings @ 0.8 PF

Voltage*

230/400 V

Frequency*

50 Hz

Prime rating

CT2250*

2250 KVA

Stand-by Rating

CT2500s*

2500 KVA

Ghaddar Generator CT2250 – CT2500S (50 Hz) powered by Cummins

The above ratings represent the generating set capability guaranteed within ±3% at the reference conditions equivalent to those specified in ISO 8528/1 standard.

Notes

  1. The applicable voltage range is 380V to 415V for 50Hz applications. For other voltages, please consult factory.
  2. This generating set is of fixed speed of 1500 rpm.
  3. CT2250 is the prime power rating of the generating set where a variable load and unlimited hour usage are applied with an average load factor of 80% of the prime rating over each 24-hour period. A 10% overload is permitted for 1 hour in every 12-hour operation.
  4. CT2500S is the standby power rating of the generating set where a variable load limited to an annual usage up to 500 hours is applied, with 300 hours of which may be continuous running. No overload is permitted.

Engine Technical Data

Make & ModelCUMMINS QSK60-G8
Cylinders & Arrangement16; 60º Vee
Bore & Stroke (mm)159×190
Induction systemTurbo Charged & Aftercooled
CombustionDirect injection
Cycle4 stroke
Compression ratio14:5:1
Cooling SystemWater cooled
Displacement60.2 liters
Lube oil capacity197 liters Max
Coolant capacity560 liters
Standard governorElectronic
Engine Speed1500 rpm
Consumption @ 100% Load (L/H)448
Consumption @ 75% Load (L/H)334
Consumption @ 50% Load (L/H)228
Consumption @ 25% Load (L/H)125
Radiator Cooling Air Flow (m3/s)30.3
Emissions regulationsFor non-regulated territories
Exhaust temperature ᵒC (max)430
Max exhaust gas flow (m3/min)311.4
Max. allowed back pressure (kPa)6.8

The above performance data are valid as per the following specs:

  • Diesel Fuel is according to BS2869 Class A2 or equivalent.
  • Lubricating oil is according to Grade SAE 15W-40 API CI4.
  • The coolant should be 50% antifreeze and 50% fresh water.

Alternator Technical Data

Make & ModelLeroy Somer LSA52.3L9
Frequency / No. of poles50Hz / 4P
Ingress protectionIP23
Insulation classH
Terminals (Optional)6 (12)
Excitation systemAREP + PMI
Winding pitch2/3
AVR modelD 550C
Overspeed2250 R.P.M.
Voltage regulation± 0.5 %
Coolant air flow2.5 m3/s

Certification

  • The complete generating set is type-tested according to ISO 8528-8 standard.

Control Panel Specifications

GMP260MKIII (DSE6110 MKIII) panel is an automatic start genset panel of microprocessor-based design, capable of CAN-bus J1939 interface with electronic engines. Configurable via PC software or fascia buttons.
Optional DSE6120MKIII for mains monitoring. Circuit breaker: Schneider or ABB, 3P MCB (4P optional).

Construction

Sheet FabricationCNC shearing & bending
Paint typeHeat-treated powder-coated
Paint applicationElectrostatic corona spraying
Durability tests
  • Impact [EN ISO 6272]
  • Salt spray resistance [ASTM B117-73]
  • Humidity resistance [ASTM D2247]
Compliance
  • Compliant with [ISO8528-8]
  • Clearance & Creepage [IEC60355-1]
  • Leakage current & Dielectric strength [IEC60355-1]
  • Protection against electric shock [IEC600 364-4-41]
Degree of protectionIP55
Wire crimping
  • Crimping force up to 20 kN
  • Accuracy of 0.01 mm
  • Each crimp checked by Komax CFA+
Wire coding
  • Coded by color and cross-section
  • Coded by printed numbers
  • Coded by printed function of the wire

Certification

  • The control panel is certified by an ISO17025 accredited laboratory to have IP55 according to IEC60355.

Genset Standard Features

Assembly: Gensets are assembled at Ghaddar Machinery Factory in compliance with ISO 8528.

Fabrication:

  • Engine/alternator assembly rests on skid with anti-vibration mounting pads.
  • Skid made of durable sheet metals and beams exceeding “Vibration & Torsion” resistance norms.
  • Skid-mounted fuel tank supplied with fuel gauge, filler cap, fuel inlet and outlet hoses.
  • Control panel enclosure made of reliable metal sheet.

Paint:

  • Skid and control panel enclosure painted with heat-treated, powder-coated electrostatic corona spraying.
  • Paint durability tested against:
    • Impact (EN ISO 6272)
    • Salt Spray Resistance (ASTM B117-73)
    • Humidity Resistance (ASTM D2247)

Works-Testing:

  • All gensets tested prior to dispatch.
  • Test automatically generated and checked according to ISO8528.
  • Test certificate issued for each genset.

Equipment:

  • Water-cooled radiator with belt-driven blower fan and full guarding
  • Electric starter with solenoid relay
  • Battery charging alternator
  • Energized-to-run solenoid
  • Replaceable fuel, oil and air filters
  • Heavy-duty lead-acid battery with matching capacity (Amps & CCA)
  • Industrial exhaust silencer – 16 dB noise reduction.

Documentation:

  • User Manual (Operation, Installation, Maintenance)
  • Wiring Diagram
  • Test Report
  • Maintenance Schedule
  • Catalogues for Engine, Alternator & AVR

Genset Optional Features

  • Manual & Automatic Transfer Switches
  • Synchronizing & Totalizing Panels
  • Fuel water separator
  • Water jacket heater
  • Oil heater
  • Fuel heater
  • Battery heater
  • Anti-condensation heater
  • Air Shut-off Valve
  • Oil Sampler
  • Pre-lube Oil Pump

Shipping Dimensions (Open Set):

  • Length: 5900 mm
  • Width: 2300 mm
  • Height: 2750 mm
  • Weight: 15500 Kg